Skip to content

Sensor Mappings

slipx06 edited this page May 19, 2023 · 7 revisions

Solar

Card Attribute Modbus Register Unit Sunsynk Solarman E-Linter (template sensor)
pv1_power_186 186 1W PV1 input power PV1 Power {{state_attr('sensor.sunsynk_input', 'pv1')
pv2_power_187 187 1W PV2 input power PV2 Power {{state_attr('sensor.sunsynk_input', 'pv2')
pv3_power_188 188 1W PV3 input power {{state_attr('sensor.sunsynk_input', 'pv3')
pv4_power_189 189 1W PV4 input power {{state_attr('sensor.sunsynk_input', 'pv4')
pv1_v_109 109 0.1V DC voltage 1 PV1 Voltage {{state_attr('sensor.sunsynk_input', 'pvIV_0_vpv')
pv2_v_111 111 0.1V DC voltage 2 PV2 Voltage {{state_attr('sensor.sunsynk_input', 'pvIV_1_vpv')
pv3_v_113 113 0.1V DC voltage 3 {{state_attr('sensor.sunsynk_input', 'pvIV_2_vpv')
pv4_v_115 115 0.1V DC voltage 4 {{state_attr('sensor.sunsynk_input', 'pvIV_3_vpv')
pv1_i_110 110 0.1A DC current 1 PV1 Current {{state_attr('sensor.sunsynk_input', 'pvIV_0_ipv')
pv2_i_112 112 0.1A DC current 2 PV2 Current {{state_attr('sensor.sunsynk_input', 'pvIV_1_ipv')
pv3_i_114 114 0.1A DC current 3 {{state_attr('sensor.sunsynk_input', 'pvIV_2_ipv')
pv4_i_116 116 0.1A DC current 4 {{state_attr('sensor.sunsynk_input', 'pvIV_3_ipv')
solarday_108 108 0.1kWh Day PV PowerWh Daily Production {{state_attr('sensor.sunsynk_input', 'etoday')

Battery

Card Attribute Modbus Register Unit Sunsynk Solarman E-Linter (template sensor)
batchargeday_70 70 0.1kWh Day_Batt_Charge _PowerWh {{state_attr('sensor.sunsynk_battery', 'etodayChg')
batdischargeday_71 71 0.1kWh Day_Batt_Discharge_PowerWh {{state_attr('sensor.sunsynk_battery', 'etodayDischg')
battery_out_190 190 1W Battery output power Battery Power {{state_attr('sensor.sunsynk_battery', 'power')
battery_voltage_183 183 0.01V Battery voltage Battery Voltage {{state_attr('sensor.sunsynk_battery', 'voltage')
battery_soc_184 184 1% Battery capacity Battery SOC {{state_attr('sensor.sunsynk_battery', 'soc')
battery_current_191 191 0.01A Battery output current {{state_attr('sensor.sunsynk_battery', 'current')

Grid

Card Attribute Modbus Register Unit Sunsynk Solarman E-Linter (template sensor)
inverter_load_grid_169 169 1W L1L2 Total power of grid side L1L2 Total Grid Power {{state_attr('sensor.sunsynk_grid', 'power')
grid_buy_day_76 76 0.1kWh Day_GridBuy_Power Wh Daily Energy Bought {{state_attr('sensor.sunsynk_grid', 'etodayFrom')
grid_sell_day_77 77 0.1kWh Day_GridSell_Power Wh Daily Energy Sold {{state_attr('sensor.sunsynk_grid', 'etodayTo')
grid_external_power_172 172 1W Grid external Total Power External CT L1 Power + External CT L2 Power {{state_attr('sensor.sunsynk_grid', 'limiterTotalPower')

Load

Card Attribute Modbus Register Unit Sunsynk Solarman E-Linter (template sensor)
essential_power 178* 1W Load side Total power Total Load Power {{state_attr('sensor.sunsynk_load', 'totalpower')
loadday_84 84 0.1kWh SG:Day_Load_Power Wh Daily Load Consumption {{state_attr('sensor.sunsynk_load', 'dailyUsed')
aux_power_166 166 1W GenGen Do micro inverse power input Micro-inverter Power {{state_attr('sensor.sunsynk_output', 'poweraux')

*Calculated through internal card logic if non-essential is used

Inverter

Card Attribute Modbus Register Unit Sunsynk Solarman E-Linter (template sensor)
use_timer_248 248 0/1 Time of Use Selling enabled {% if state_attr('sensor.sunsynk_settings', 'peakAndVallery') == 1 %} on {% else %} off {% endif %}
priority_load_243 243 0/1 Energy management model {% if state_attr('sensor.sunsynk_settings', 'energyMode:') == 1 %} on {% else %} off {% endif %}
inverter_grid_voltage_154 154 0.1V L1-N Inverter output voltage L1-N Grid Voltage L1 {{state_attr('sensor.sunsynk_output', 'vip_0_volt')
inverter_load_freq_192 192 0.01Hz L Load frequency Load Frequency {{state_attr('sensor.sunsynk_output', 'fac')
inverter_out_164 164 0.01A L1 Inverter output current L1 Current L1 {{state_attr('sensor.sunsynk_output', 'vip_0_current')
inverter_out_175 175 1W Inverter output Total power Total Power {{state_attr('sensor.sunsynk_output', 'totalpower')
grid_status_194 194 0/1 Grid side relay status Grid-connected Status {{state_attr('sensor.sunsynk_grid', 'gridonline')
inverter_status_59 59 [0-5] Run state Running Status {{ state_attr("sensor.sunsynk_invertor_list", "infos_0_gatewayVO_status") }}
Clone this wiki locally