Card Attribute | Modbus Register | Unit | Sunsynk | Solarman | E-Linter (template sensor) |
---|---|---|---|---|---|
pv1_power_186 | 186 | 1W | PV1 input power | PV1 Power | {{state_attr('sensor.sunsynk_input', 'pv1') |
pv2_power_187 | 187 | 1W | PV2 input power | PV2 Power | {{state_attr('sensor.sunsynk_input', 'pv2') |
pv3_power_188 | 188 | 1W | PV3 input power | {{state_attr('sensor.sunsynk_input', 'pv3') | |
pv4_power_189 | 189 | 1W | PV4 input power | {{state_attr('sensor.sunsynk_input', 'pv4') | |
pv1_v_109 | 109 | 0.1V | DC voltage 1 | PV1 Voltage | {{state_attr('sensor.sunsynk_input', 'pvIV_0_vpv') |
pv2_v_111 | 111 | 0.1V | DC voltage 2 | PV2 Voltage | {{state_attr('sensor.sunsynk_input', 'pvIV_1_vpv') |
pv3_v_113 | 113 | 0.1V | DC voltage 3 | {{state_attr('sensor.sunsynk_input', 'pvIV_2_vpv') | |
pv4_v_115 | 115 | 0.1V | DC voltage 4 | {{state_attr('sensor.sunsynk_input', 'pvIV_3_vpv') | |
pv1_i_110 | 110 | 0.1A | DC current 1 | PV1 Current | {{state_attr('sensor.sunsynk_input', 'pvIV_0_ipv') |
pv2_i_112 | 112 | 0.1A | DC current 2 | PV2 Current | {{state_attr('sensor.sunsynk_input', 'pvIV_1_ipv') |
pv3_i_114 | 114 | 0.1A | DC current 3 | {{state_attr('sensor.sunsynk_input', 'pvIV_2_ipv') | |
pv4_i_116 | 116 | 0.1A | DC current 4 | {{state_attr('sensor.sunsynk_input', 'pvIV_3_ipv') | |
solarday_108 | 108 | 0.1kWh | Day PV PowerWh | Daily Production | {{state_attr('sensor.sunsynk_input', 'etoday') |
Card Attribute | Modbus Register | Unit | Sunsynk | Solarman | E-Linter (template sensor) |
---|---|---|---|---|---|
batchargeday_70 | 70 | 0.1kWh | Day_Batt_Charge _PowerWh | {{state_attr('sensor.sunsynk_battery', 'etodayChg') | |
batdischargeday_71 | 71 | 0.1kWh | Day_Batt_Discharge_PowerWh | {{state_attr('sensor.sunsynk_battery', 'etodayDischg') | |
battery_out_190 | 190 | 1W | Battery output power | Battery Power | {{state_attr('sensor.sunsynk_battery', 'power') |
battery_voltage_183 | 183 | 0.01V | Battery voltage | Battery Voltage | {{state_attr('sensor.sunsynk_battery', 'voltage') |
battery_soc_184 | 184 | 1% | Battery capacity | Battery SOC | {{state_attr('sensor.sunsynk_battery', 'soc') |
battery_current_191 | 191 | 0.01A | Battery output current | {{state_attr('sensor.sunsynk_battery', 'current') |
Card Attribute | Modbus Register | Unit | Sunsynk | Solarman | E-Linter (template sensor) |
---|---|---|---|---|---|
inverter_load_grid_169 | 169 | 1W | L1L2 Total power of grid side L1L2 | Total Grid Power | {{state_attr('sensor.sunsynk_grid', 'power') |
grid_buy_day_76 | 76 | 0.1kWh | Day_GridBuy_Power Wh | Daily Energy Bought | {{state_attr('sensor.sunsynk_grid', 'etodayFrom') |
grid_sell_day_77 | 77 | 0.1kWh | Day_GridSell_Power Wh | Daily Energy Sold | {{state_attr('sensor.sunsynk_grid', 'etodayTo') |
grid_external_power_172 | 172 | 1W | Grid external Total Power | External CT L1 Power + External CT L2 Power | {{state_attr('sensor.sunsynk_grid', 'limiterTotalPower') |
Card Attribute | Modbus Register | Unit | Sunsynk | Solarman | E-Linter (template sensor) |
---|---|---|---|---|---|
essential_power | 178* | 1W | Load side Total power | Total Load Power | {{state_attr('sensor.sunsynk_load', 'totalpower') |
loadday_84 | 84 | 0.1kWh | SG:Day_Load_Power Wh | Daily Load Consumption | {{state_attr('sensor.sunsynk_load', 'dailyUsed') |
aux_power_166 | 166 | 1W | GenGen Do micro inverse power input | Micro-inverter Power | {{state_attr('sensor.sunsynk_output', 'poweraux') |
*Calculated through internal card logic if non-essential is used
Card Attribute | Modbus Register | Unit | Sunsynk | Solarman | E-Linter (template sensor) |
---|---|---|---|---|---|
use_timer_248 | 248 | 0/1 | Time of Use Selling enabled | {% if state_attr('sensor.sunsynk_settings', 'peakAndVallery') == 1 %} on {% else %} off {% endif %} | |
priority_load_243 | 243 | 0/1 | Energy management model | {% if state_attr('sensor.sunsynk_settings', 'energyMode:') == 1 %} on {% else %} off {% endif %} | |
inverter_grid_voltage_154 | 154 | 0.1V | L1-N Inverter output voltage L1-N | Grid Voltage L1 | {{state_attr('sensor.sunsynk_output', 'vip_0_volt') |
inverter_load_freq_192 | 192 | 0.01Hz L | Load frequency | Load Frequency | {{state_attr('sensor.sunsynk_output', 'fac') |
inverter_out_164 | 164 | 0.01A | L1 Inverter output current L1 | Current L1 | {{state_attr('sensor.sunsynk_output', 'vip_0_current') |
inverter_out_175 | 175 | 1W | Inverter output Total power | Total Power | {{state_attr('sensor.sunsynk_output', 'totalpower') |
grid_status_194 | 194 | 0/1 | Grid side relay status | Grid-connected Status | {{state_attr('sensor.sunsynk_grid', 'gridonline') |
inverter_status_59 | 59 | [0-5] | Run state | Running Status | {{ state_attr("sensor.sunsynk_invertor_list", "infos_0_gatewayVO_status") }} |