CHAD-14369 Add ezex valve sub-driver
Old version of this valve use the IAS Zone Status to report low battery and do not otherwise support the PowerConfiguration cluster, which is usually used for reporting the battery. The porting work done for the DTH missed this behavior because it was removed. This adds back in the old behavior, but only for devices that do not support PowerConfiguration, which should be rare, as the old behavior is not ideal.
- Loading branch information
Showing
3 changed files
with
403 additions
and
1 deletion.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,80 @@ | ||
-- Copyright 2024 SmartThings | ||
-- | ||
-- Licensed under the Apache License, Version 2.0 (the "License"); | ||
-- you may not use this file except in compliance with the License. | ||
-- You may obtain a copy of the License at | ||
-- | ||
-- http://www.apache.org/licenses/LICENSE-2.0 | ||
-- | ||
-- Unless required by applicable law or agreed to in writing, software | ||
-- distributed under the License is distributed on an "AS IS" BASIS, | ||
-- WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. | ||
-- See the License for the specific language governing permissions and | ||
-- limitations under the License. | ||
|
||
local clusters = require "st.zigbee.zcl.clusters" | ||
local capabilities = require "st.capabilities" | ||
|
||
local IASZone = clusters.IASZone | ||
local Basic = clusters.Basic | ||
local OnOff = clusters.OnOff | ||
|
||
local configuration = { | ||
{ | ||
cluster = IASZone.ID, | ||
attribute = IASZone.attributes.ZoneStatus.ID, | ||
minimum_interval = 0, | ||
maximum_interval = 3600, | ||
data_type = IASZone.attributes.ZoneStatus.base_type, | ||
reportable_change = 1 | ||
}, | ||
{ | ||
cluster = Basic.ID, | ||
attribute = Basic.attributes.PowerSource.ID, | ||
minimum_interval = 30, | ||
maximum_interval = 21600, | ||
data_type = Basic.attributes.PowerSource.base_type, | ||
}, | ||
{ | ||
cluster = OnOff.ID, | ||
attribute = OnOff.attributes.OnOff.ID, | ||
minimum_interval = 0, | ||
maximum_interval = 600, | ||
data_type = OnOff.attributes.OnOff.base_type | ||
} | ||
} | ||
|
||
local function ias_zone_status_attr_handler(driver, device, zone_status, zb_rx) | ||
-- this is cribbed from the DTH | ||
if zone_status:is_battery_low_set() then | ||
device:emit_event(capabilities.battery.battery(5)) | ||
else | ||
device:emit_event(capabilities.battery.battery(50)) | ||
end | ||
end | ||
|
||
local function device_init(driver, device) | ||
for _, attribute in ipairs(configuration) do | ||
device:add_configured_attribute(attribute) | ||
device:add_monitored_attribute(attribute) | ||
end | ||
end | ||
|
||
local ezex_valve = { | ||
NAME = "Ezex Valve", | ||
zigbee_handlers = { | ||
attr = { | ||
[IASZone.ID] = { | ||
[IASZone.attributes.ZoneStatus.ID] = ias_zone_status_attr_handler | ||
}, | ||
} | ||
}, | ||
lifecycle_handlers = { | ||
init = device_init | ||
}, | ||
can_handle = function(opts, driver, device, ...) | ||
return device:get_model() == "E253-KR0B0ZX-HA" and not device:supports_server_cluster(clusters.PowerConfiguration.ID) | ||
end | ||
} | ||
|
||
return ezex_valve |