library (
base: "driver",
author: "jvm33",
category: "zwave",
description: "Handle Interactions with the Hubitat Hub",
name: "versionInfoTools",
namespace: "zwaveTools",
documentationLink: "https://github.com/jvmahon/HubitatDriverTools",
version:"0.0.1",
dependencies: "none",
librarySource:"https://raw.githubusercontent.com/jvmahon/HubitatDriverTools/main/versionInfoTools.groovy"
)
void zwaveEvent(hubitat.zwave.commands.versionv3.VersionReport cmd) {
log.info "Version report: ${cmd}"
String thisDeviceVersion
thisDeviceVersion = "${cmd.firmware0Version}." + "${cmd.firmware0SubVersion}".padLeft(3,"0")
updateDataValue("mainFirmwareVersion", thisDeviceVersion)
updateDataValue("hardwareVersion", "${cmd.hardwareVersion}")
}
void versionInfoTools_refreshVersionInfo() {
advancedZwaveSend(zwave.versionV3.versionGet())
}
void zwaveEvent(hubitat.zwave.commands.firmwareupdatemdv6.FirmwareUpdateMdGet cmd) {
log.info "Device ${device.displayName}: Firmware Update in Progress. Report No. ${cmd.reportNumber}"
}
void zwaveEvent(hubitat.zwave.commands.firmwareupdatemdv6.FirmwareUpdateMdRequestReport cmd) {
String statusReport = [
0x01:"ERROR. Invalid combination of Manufacturer ID and Firmware ID. The device will not initiate the firmware update.",
0x02:"ERROR. Device expected an authentication event to enable firmware update. The device will not initiate the firmware update.",
0x03:"ERROR. The requested Fragment Size exceeds the Max Fragment Size. The device will not initiate the firmware update.",
0x04:"ERROR. This firmware target is not upgradable. The device will not initiate the firmware update.",
0x05:"ERROR. Invalid Hardware Version. The device will not initiate the firmware update.",
0x06:"ERROR: Another firmware image is current being transferred. The device will not initiate the firmware update.",
0x07:"ERROR: Insufficient battery level. The device will not initiate the firmware update.",
0x08:"OK. The device will initiate the firmware update of the target specified in the Firmware Update Meta Data Request Get Command."
].get((int) cmd.status)
log.info "Device ${device.displayName}: Firmware Update Report: ${statusReport}"
}
void zwaveEvent(hubitat.zwave.commands.firmwareupdatemdv6.FirmwareMdReport cmd) {
log.info "Device ${device.displayName}: Firmware Update in Progress. Received FirmwareMdReport: ${cmd}"
}
void refreshManufacturerSpecificInfo() {
advancedZwaveSend(zwave.manufacturerSpecificV2.manufacturerSpecificGet())
}
void zwaveEvent(hubitat.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
if (txtEnable) log.info "Received ManufacturerSpecificReport: ${cmd}"
updateDataValue("deviceType", "${cmd.productTypeId}")
updateDataValue("deviceId", "${cmd.productId}")
updateDataValue("manufacturer", "${cmd.manufacturerId}")
}