-- Check the wiki at
-- http://www.domoticz.com/wiki/%27dzVents%27:_next_generation_LUA_scripting
return {
-- 'active' controls if this entire script is considered or not
active = true, -- set to false to disable this script
-- trigger
-- can be a combination:
on = {
timer = {
-- timer triggers.. if one matches with the current time then the script is executed
'every minute'
},
devices = {
15, 60
}
},
-- actual event code
-- in case of a timer event or security event, device == nil
execute = function(domoticz, device)
--[[
The domoticz object holds all information about your Domoticz system. E.g.:
local myDevice = domoticz.devices('myDevice')
local myVariable = domoticz.variables('myUserVariable')
local myGroup = domoticz.groups('myGroup')
local myScene = domoticz.sceneds('myScene')
The device object is the device that was triggered due to the device in the 'on' section above.
]] --
-- example
if (domoticz.globalData.pirDisabled) then
domoticz.log('Exiting PIR inactivity script because PIR is disabled.')
return
end
local switchSleepMode = domoticz.devices(138)
local switchNightMode = domoticz.devices(139)
local switchDayMode = domoticz.devices(140)
local pir01 = domoticz.devices(15)
local wdw01 = domoticz.devices(60)
local dim08 = domoticz.devices(219)
-- when the script was triggered by the pir sensor, we need to check whether the light should be activated
if (device ~= nil and (device.id == pir01.id or device.id == wdw01.id)) then
local level = 0
if (switchSleepMode.state == "On") then
level = 20
elseif (switchNightMode.state == "On") then
level = 40
elseif (switchDayMode.state == "On") then
return
end
dim08.dimTo(level)
domoticz.log('Switched on lights in downstairs hallway as EYE01 detected motion at night time.')
-- this should go INSIDE the if loop
local Time = require('Time')
local currentTime = Time().raw
domoticz.log('storing the activation time in global: ' .. tostring(currentTime))
domoticz.globalData.pir01Activation.add(currentTime)
return
end
local inactivityPeriod = 15
local Time = require('Time')
local lastActivationRaw = domoticz.globalData.pir01Activation.getLatest().data
local lastUpdate = pir01.lastUpdate
if (lastActivationRaw ~= nil) then
local lastActivationTime = Time(lastActivationRaw)
local currentTime = Time()
local minutesActivated = lastActivationTime.compare(lastUpdate)
if (minutesActivated.mins < 10) then
inactivityPeriod = minutesActivated.mins
else
inactivityPeriod = 10
end
end
local timeLastUpdate = lastUpdate.minutesAgo
local tmpBool = lastUpdate.minutesAgo >= inactivityPeriod
if (pir01.state == 'Off' and lastUpdate.minutesAgo > inactivityPeriod and dim08.state ~= 'Off') then
dim08.switchOff()
domoticz.log('Switched off hallway lights downstairs because of PIR inactivity')
end
end
}