-
Notifications
You must be signed in to change notification settings - Fork 62
/
ruuvi-collector.properties.example
98 lines (78 loc) · 5.48 KB
/
ruuvi-collector.properties.example
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
# These are the defaults
# Copy this file as "ruuvi-collector.properties" to the same directory as the collector application itself is and
# uncomment the lines and change the values, if you need
# Base url to connect to, including protocol, hostname or ip address, and port
#influxUrl=http://localhost:8086
# InfluxDB Database to use for measurements
#influxDatabase=ruuvi
# InfluxDB measurement name to use for measurements
#influxMeasurement=ruuvi_measurements
# Username and password to use in influxdb. These can be ignored if you don't use authentication in InfluxDB.
#influxUser=ruuvi
#influxPassword=ruuvi
# Minimum interval in milliseconds for measurements per measurement type per tag.
# This is to avoid saving too many measurements especially with the default firmware which sends measurements every 0.5 seconds
# For example 9900 means post at most one measurement type per tag per 9.9 seconds
#measurementUpdateLimit=9900
# Limiting strategy, currently valid values: "default" and "defaultWithMotionSensitivity".
# The default in both is to discard packets and only to save a packet every [measurementUpdateLimit] milliseconds
# (see above). Additionally, the "defaultWithMotionSensitivity" strategy saves packets that exhibit sudden acceleration
# changes. The exact threshold is configurable using the limitingStrategy.defaultWithMotionSensitivity.threshold
# property.
#limitingStrategy=default
# Note, the value below has no effect if "default" has been set as the limiting strategy above.
# Value of "1" corresponds to 1 G. The default is 0.05, i.e. 50 mG.
#limitingStrategy.defaultWithMotionSensitivity.threshold=0.05
# Filtering for sources based on the source MAC address (blacklist or whitelist)
# Valid values "none", "blacklist" and "whitelist".
# none = Allows any source to be stored (default)
# blacklist = Allows all sources EXCEPT those listed
# whitelist = Allows ONLY sources that are listed in filter.macs
# named = Allows ONLY sources that are listed in ruuvi-names.properties
#filter.mode=none
# Mac addresses to blacklist/whitelist. This has no effect if filter.mode is set to none
#filter.macs=ABCDEF012345,F1E2D3C4B5A6
# Storage method, currently valid values: "influxdb", "legacy_influxdb", "prometheus" and "dummy"
# influxdb = Recommended and default, this stores the values to InfluxDB into a single measurement
# influxdb_legacy = The old format used by this collector on versions before 0.2.0, stores values into separate measurements.
# NOTE: influxdb_legacy is no longer supported, you should use the new influxdb format and migrate old data, see CHANGELOG.md
# dummy = Logs the measurements to the log rather than sending them anywhere, feasible for testing and development
#storage.method=influxdb
# A receiver identifier to tag values written by this instance to influxdb.
# You could put in e.g. your host name or bluetooth receiver MAC here.
#receiver=
# Values to store, the collector is capable of calculating additional values from the values received from a tag, for example absolute humidity and dew point
# Valid values "raw", "extended", "whitelist", "blacklist":
# raw = Save only the raw values received from the tag. Ignores the storage.values.list property.
# extended = In addition to the above, calculate additional values such as absolute humidity, dew point, total acceleration and air density.
# Ignores the storage.values.list property. NOTE: the influxdb_legacy storage method does not support extended values
# whitelist = Only the values given in the storage.values.list property are stored. (influxdb_legacy storage method not supported.)
# blacklist = Only the values not given in the storage.values.list property are stored. (influxdb_legacy storage method not supported.)
#storage.values=extended
# See MEASUREMENTS.md for all the field names that can be used with storage.values.list.
# Note that leaving this list empty while setting storage.values=whitelist results in an exception: no sensor data
# would be stored with this combination. Setting storage.values=blacklist and leaving this list empty only results
# in a warning, as that is essentially just the same as setting storage.values=extended -- nothing is banned.
#storage.values.list =
#
# Advanced configuration - Change these only if you know what you are doing
#
# Commands for starting the BLE scanning and the dump.
# The scan command is only executed, output and exit is ignored. Setting this blank will disable this command.
# The dump command is executed and it's output is parsed, the collector will exit when/if this command ends
# In general you want to change these only if you intend to use wrapper scripts or you need to use absolute paths to the executables
#command.scan=hcitool lescan --duplicates --passive
#command.dump=hcidump --raw
# Retention policy to use (note: you must create it yourself)
#influxRetentionPolicy=autogen
# Use gzip, saves bandwidth at minimal CPU cost
#influxGzip=true
# Use batch mode, improved performance at the cost of increased delay for measurements to show up. Does not affect the timestamps.
#influxBatch=true
# Exit when InfluxDB connection is lost so systemd can take action (disabled by
# default for backward compatibility, requires influxBatch to be false to take
# effect due to limitations of the InfluxDB library)
#exitOnInfluxDBIOException=false
# Maximum number of datapoints and maximum time waited in milliseconds before sending a batch. Has no effect if batch mode disabled.
#influxBatchMaxSize=2000
#influxBatchMaxTime=100