Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

--min-freq-for-hom in VarScan #1

Open
billzt opened this issue Oct 8, 2017 · 0 comments
Open

--min-freq-for-hom in VarScan #1

billzt opened this issue Oct 8, 2017 · 0 comments

Comments

@billzt
Copy link

billzt commented Oct 8, 2017

https://github.com/OpenGene/ctdna-pipeline/blob/master/pipeline.sh#L24 says:

java -jar VarScan.v2.3.8.jar mpileup2snp outdir/test.dedup.mpileup --min-coverage 4 --min-reads2 2 --min-avg-qual 20 --min-var-freq 0.001 --min-freq-for-hom 90 --output-vcf 1 >outdir/test.snp.vcf

Now I'm not sure whether the value of --min-freq-for-hom 90 is OK. Because now the new version of VarScan (v2.4.3) says:

USAGE: java -jar VarScan.jar mpileup2cns [pileup file] OPTIONS
        mpileup file - The SAMtools mpileup file

        OPTIONS:
...
        --min-freq-for-hom      Minimum frequency to call homozygote [0.75]
...

Note, the default value is 0.75 rather than 75 (%). Therefore perhaps we should use value 0.9 rather than 90 (5)