More confusing things while looking into this, I tried generated the payload in zhc to see if I could at least get the write to work without messing with herdsman yet. + const cluster = Zcl.Utils.getCluster('manuSpecificUbisysDeviceSetup');
+ const attributes = {'inputActions': {elementType: 'octetStr', elements: resultingInputActions}};
+ const payload: {attrId: number; dataType: number; attrData: number| string | boolean}[] = [];
+ for (const [nameOrID, value] of Object.entries(attributes)) {
+ if (cluster.hasAttribute(nameOrID)) {
+ const attribute = cluster.getAttribute(nameOrID);
+ payload.push({attrId: attribute.ID, attrData: value, dataType: attribute.type});
+ } else if (!isNaN(Number(nameOrID))){
+ // NOTE: tsc trisp here, but we take the prev branch
+ //payload.push({attrId: Number(nameOrID), attrData: value.value, dataType: value.type});
+ } else {
+ throw new Error(`Unknown attribute '${nameOrID}', specify either an existing attribute or a number`);
+ }
+ }
+
+ await devMgmtEp.writeStructured(
+ 'manuSpecificUbisysDeviceSetup',
+ payload,
+ manufacturerOptions.ubisysNull,
+ );
+ /*
await devMgmtEp.write(
'manuSpecificUbisysDeviceSetup',
{'inputActions': {elementType: 'octetStr', elements: resultingInputActions}},
manufacturerOptions.ubisysNull,
);
+ */ TSC is very much not happy with this:
Which leaves me very confused as the original write passes Edit 1: zigbee-herdsman/src/zcl/buffaloZcl.ts Lines 160 to 167 in 487996a
Which would make sense given this attribute is an array (ZCL data type 0x48) of raw binary data (ZCL data type 0x41). Edit 2:
Seems to work |
This issue is stale because it has been open 180 days with no activity. Remove stale label or comment or this will be closed in 30 days |
Unstale |
This issue is stale because it has been open 180 days with no activity. Remove stale label or comment or this will be closed in 30 days |
Ubisys changed to this for their switch configuration, so we would need this to fix Koenkk/zigbee2mqtt#15875
My initial attempt simple swapped the current
write()
call's towriteStructure()
call's but that does not work.https://github.com/Koenkk/zigbee-herdsman-converters/blob/b9f29f55d3f0531c9235e38a6848908c9a493042/src/devices/ubisys.ts#L509-L512
It seems our current
endpoint.write()
does some handling for the attribute data to generate a payload to pass toZcl.ZclFrame.create()
.zigbee-herdsman/src/controller/model/endpoint.ts
Lines 358 to 399 in 487996a
This is missing in
endpoint.writeStructured()
zigbee-herdsman/src/controller/model/endpoint.ts
Lines 700 to 724 in 487996a
Which seems to expect a raw payload that is passed to
Zcl.ZclFrame.create()
.We should probably update this one and also add the missing writeStructuredResponse and readStructure* variants as we probably also want to be able to read the data we write. Perhaps this can be done when we do #902.
So far there is only one usage of
endpoint.writeStructured()
here https://github.com/Koenkk/zigbee-herdsman-converters/blob/b9f29f55d3f0531c9235e38a6848908c9a493042/src/converters/toZigbee.ts#L2082The text was updated successfully, but these errors were encountered: