It would be important to limit the valves in the valve position. I live in an old house and the valves are all from before the time of hydraulic balancing as a valve setting. Due to the self-learning curve, the system swings up to such an extent that the wood-burning stove with buffer storage tank is constantly switching back and forth between oil heating and wood-burning stove if everything is not running at full throttle due to the rapid switching on and off of the algos when the temperature drops more if, for example, the door is open for a few minutes.
Description
The next one would be a problem, but it also fits in here. Better thermostat does not run at max eq3. After 1.5 days, the duty cycle of 4 test thermostats reaches a value that exceeds the 1 per cent duty cycle of the cube, which is why it simply shuts down the entire control system until the duty cycle returns to the 1 per cent mark after 1 hour. Also, the whole system crashes when the integrated window sensors switch and better thermostat then tries to adjust the temperature, which the cube does not allow when the window is open.
best regards
Ralf :-)
Additional Information
The text was updated successfully, but these errors were encountered:
What is the feature?
It would be important to limit the valves in the valve position. I live in an old house and the valves are all from before the time of hydraulic balancing as a valve setting. Due to the self-learning curve, the system swings up to such an extent that the wood-burning stove with buffer storage tank is constantly switching back and forth between oil heating and wood-burning stove if everything is not running at full throttle due to the rapid switching on and off of the algos when the temperature drops more if, for example, the door is open for a few minutes.
Description
The next one would be a problem, but it also fits in here. Better thermostat does not run at max eq3. After 1.5 days, the duty cycle of 4 test thermostats reaches a value that exceeds the 1 per cent duty cycle of the cube, which is why it simply shuts down the entire control system until the duty cycle returns to the 1 per cent mark after 1 hour. Also, the whole system crashes when the integrated window sensors switch and better thermostat then tries to adjust the temperature, which the cube does not allow when the window is open.