void backflowControl(){ //PV BACKFLOW CONTROL (INPUT MOSFET)
if(output_Mode==0){bypassEnable=1;} //PSU MODE: Force backflow MOSFET on
else{ //CHARGER MODE: Force backflow MOSFET on
if(voltageInput>voltageOutput+voltageDropout){bypassEnable=1;} //CHARGER MODE: Normal Condition - Turn on Backflow MOSFET (on by default when not in MPPT charger mode)
else{bypassEnable=0;} //CHARGER MODE: Input Undervoltage - Turn off bypass MOSFET and prevent PV Backflow (SS)
}
digitalWrite(backflow_MOSFET,bypassEnable); //Signal backflow MOSFET GPIO pin
}
void Device_Protection(){
//ERROR COUNTER RESET
currentRoutineMillis = millis();
if(currentErrorMillis-prevErrorMillis>=errorTimeLimit){ //Run routine every millisErrorInterval (ms)
prevErrorMillis = currentErrorMillis; //Store previous time
if(errorCount<errorCountLimit){errorCount=0;} //Reset error count if it is below the limit before x milliseconds
else{} // TO ADD: sleep and charging pause if too many errors persists
}
//FAULT DETECTION
ERR = 0; //Reset local error counter
backflowControl(); //Run backflow current protection protocol
if(temperature>temperatureMax) {OTE=1;ERR++;errorCount++;}else{OTE=0;} //OTE - OVERTEMPERATURE: System overheat detected
if(currentInput>currentInAbsolute) {IOC=1;ERR++;errorCount++;}else{IOC=0;} //IOC - INPUT OVERCURRENT: Input current has reached absolute limit
if(currentOutput>currentOutAbsolute) {OOC=1;ERR++;errorCount++;}else{OOC=0;} //OOC - OUTPUT OVERCURRENT: Output current has reached absolute limit
if(voltageOutput>voltageBatteryMax+voltageBatteryThresh) {OOV=1;ERR++;errorCount++;}else{OOV=0;} //OOV - OUTPUT OVERVOLTAGE: Output voltage has reached absolute limit
if(voltageInput<vInSystemMin&&voltageOutput<vInSystemMin){FLV=1;ERR++;errorCount++;}else{FLV=0;} //FLV - Fatally low system voltage (unable to resume operation)
if(output_Mode==0){ //PSU MODE specific protection protocol
REC = 0; BNC = 0; //Clear recovery and battery not connected boolean identifiers
if(voltageInput<voltageBatteryMax+voltageDropout){IUV=1;ERR++;errorCount++;}else{IUV=0;} //IUV - INPUT UNDERVOLTAGE: Input voltage is below battery voltage (for psu mode only)
}
else{ //Charger MODE specific protection protocol
backflowControl(); //Enable backflow current detection & control
if(voltageOutput<vInSystemMin) {BNC=1;ERR++;} else{BNC=0;} //BNC - BATTERY NOT CONNECTED (for charger mode only, does not treat BNC as error when not under MPPT mode)
if(voltageInput<voltageBatteryMax+voltageDropout){IUV=1;ERR++;REC=1;}else{IUV=0;} //IUV - INPUT UNDERVOLTAGE: Input voltage is below max battery charging voltage (for charger mode only)
}
}